Search results for "Flexor tendon"
showing 2 items of 2 documents
Clinical Outcomes After Aggressive Active Early Motion and Modified Kleinert Regimens: Comparison of 2 Consecutive Cohorts
2021
Background Modern multistrand repairs can withstand forces present in active flexion exercises, and this may improve the outcomes of flexor tendon repairs. We developed a simple home-based exercise regimen with free wrist and intrinsic minus splint aimed at facilitating the gliding of the flexor tendons and compared the outcomes with the modified Kleinert regimen used previously in the same institution. Methods We searched the hospital database to identify flexor tendon repair performed before and after the new regimen was implemented and invited all patients to participate. The primary outcome was total active range of motion, and secondary outcomes were Disabilities of Arm, Shoulder, and …
Positioning of the cross-stitch on the modified Kessler core tendon suture
2018
[EN] Cryopreserved human tendons were sutured with different variations of a modified Kessler-type grasping suture in a series of different designs in order to assess the influence of the distance between the cross-stitch on the core suture (5 and 10 mm from the cut tendon edge) on the peripheral suture. An original mathematical model was employed to explain the mechanical behavior (strength, deformation, and distribution of load) of the different suture designs. The effect of the peripheral epitendinous suture, combined with the distance of the core suture, was evaluated. The variation of core suture distance had no relevant consequences on the overall resilience of the design. However, in…